Currently Visiting » Quinn Lite Home » Performance » U Values
U Values for typical wall constructions

The superior thermal properties of QUINN lite thermal blocks allow the Building Regulation requirements to be surpassed using a variety of different builds as outlined below.

WALL ELEMENT THICKNESS (mm) CALCULATED U-VALUE (W/m2K)
Render 15 0.19
Dense block100
Cavity>25
QUINN therm 60
QUINN lite B3 150
Plaster 13
 
Render 15 0.20
QUINN lite B5 100
Cavity >25
QUINN therm 60
QUINN lite B5 150
Plaster 12
 
Render 15 0.20
Dense Block 100
Cavity >25
QUINN therm 60
QUINN lite B5 215
Plaster 13
 
Render 15 0.22
QUINN lite B5 100
Cavity >25
QUINN therm 60
QUINN lite B5 100
Plaster 13
 
Render 15 0.22
QUINN lite B5 100
Cavity >25
QUINN therm 60
QUINN lite B7 100
Plaster 13
 
Render 15 0.23
Dense block 100
Cavity >25
QUINN therm 60
QUINN lite B5 150
Plaster 13
 
Render 15 0.24
Dense block 100
Cavity >25
QUINN therm 60
QUINN lite B5 100
Plaster 13
U-value=0.20w/m²k
U-value=0.20w/m²k
  1. 150mm QUINN lite (B5)
  2. 100mm QUINN lite (B5)
  3. 60mm QUINN therm
  4. Thin Joint Mortar
U-value=0.20w/m²k
U-value=0.20w/m²k
  1. 215mm QUINN lite (B5)
  2. 100mm Dense Block
  3. 60mm QUINN therm
  4. Thin Joint Mortar
  5. Traditional Mortar
U-value=0.20w/m²k
U-value=0.20w/m²k
  1. 13mm Plaster
  2. 60mm QUINN therm
  3. 100mm QUINN lite (B5)
  4. Thin Joint Mortar (B5)